Connection Configuration
Devices > Connection Configuration
Connection Configuration

A connection is composed of controllers attached to the same communication port. The system can manage up to 32 connections per multi-site Gateway. EntraPass also allows users to add up to 2048 connections per multi-site Gateway. multi-site Gateway connections are composed of KT-100, KT-200, KT-300, KT-400 and KT-1 controllers.

 

Items displayed in the EntraPass Connection window vary depending on the selected connection type. For example, if the selected connection type is an RS-232, an RS-232  tab will be displayed to configure the corresponding serial port and baud rate. If the connection type is dial-up, three extra tabs will be displayed for modem configuration.

NOTE: For a single gateway, limits are 2048 connections, 10,000 doors, 100,000 inputs and 100,000 outputs.

Seven types of connections are available: Direct (RS-232 and USB), Secure IP (KT-400), Secure IP (KTES), Secure IP (IP Link), Secure IP KT-1, Ethernet (polling) and Dial-Up (RS-232) modem. Check the following table for the connection type versus the gateway.

Connection TypeMulti-site Gateway (Note)Global Gateway (Note)KT-NCC (Note)
Direct (RS-232 or USB)YesYesYes
Ethernet (polling)YesYesYes
Secure IP (KT-1)YesYesYes
Secure IP (KT-400)YesYesYes
Secure IP (KTES)Yes 
Secure IP (IP Link)Yes
Dial-up (RS-232) modemYes
Closed Note...

1 - From the Devices window, click the Connection button.

2 - Select a Site filter from the first drop-down list.

3 - select the Gateway.

4 - From the Connection drop-down list, select the connection where the controller is located.

5 - If you are defining a new Connection , click the New button. Assign a name to the new connection and click the Save  button.

6 - Under the General tab:

•   In the Hardware definition section , specify the number of controllers for the connection. There may be up to 32 controllers per connection. If the number specified is greater than the maximum allowed, the system will set the value to 32.

Closed Note...

•  Select a Time zone: This setting will allow events from the remote site to be displayed at local gateway time on EntraPass workstations located in different time zones.

•   Select a Graphic  and Video   view  to which the gateway is assigned, if applicable. The video view will only be activated If the video feature is enabled in EntraPass.

•   Use the scroll list to select the Connection type   between the computer and the gateway. This will determine which tabs will be displayed for configuration.

ClosedSetting up Communication Timing
ClosedConfiguring a Direct RS-232 Connection Type
ClosedConfiguring an IP Device Connection Type
ClosedConfiguring an Ethernet Polling Connection Type
ClosedConfiguring a Dial-Up (RS-232) Modem Connection Type
ClosedMigrating KT-Standalone Back-up Data to an EntraPass Server

IconDescription
KT-Standalone: selects backup files from a KT-1, firmware v2.01 and higher, and the KT-401, firmware v2.00 and higher, standalone controllers.

Before you migrate your data, you must configure EntraPass to use the same card format, Global Card Format, and PIN length as the standalone settings:

1 - Navigate to the Account tab, and select System from the menu.

2 - To open the Display Format window, click the

3 - In the Default card format area, select the Card #1 format to match the Card #1 format in the standalone controller, repeat for Card # 2 to Card # 5.

NOTE: If card #1 and card #2 use a different display format, EntraPass migrates into card #4 or card #5.

4 - In the Global Card Format area, choose the appropriate global card format.

5 - Select the appropriate PIN length from the Number of PIN digits (KT-400 and KT-1) list.

 

To migrate backup data complete the following steps:

1 - On the Devices tab, select Connection from the menu.

2 - Click the KT-Standalone button on the menu bar to display the KT-standalone backup CFG files for the KT-1, firmware v2.01 and higher, and the KT-401, firmware v2.00 and higher.

3 - Select a file to see the backup information:

a - Backup date and time

b - Controller type

c - Controller MAC/Serial number

d - Controller firmware version

e - Amount of users

f - Amount of schedules

g - Amount of holidays

h - Amount of action scheduler

i - Amount of doors

j - Amount of relays

k - Amount of input

4 - A window displays with the message “Are you sure you want to import the following data?” If you click Yes: import data, the following message displays, “Migration completed”, click OK. If you click No, the message window closes.

ClosedThe Unassigned Controllers List

For more details about the Comment entry box, please refer to Comment Field.